Product Introduction
Product Usage: Widely used in petrochemical products, food, daily necessities, pharmaceuticals, pesticides, cosmetics, solvents, and other gas, liquid, and solid products.
Applicable standards: GB/T623, SH/T1144, SH/T0086, SH/T1612, GB/T606, SH/T 0246, GB/T3727, GB/T 7600.
Performance characteristics:
The electric quantity method capacity method moisture measurement integrated machine is a full range Karl Fischer moisture measurement instrument that combines two Karl Fischer moisture measurement methods, constant water measurement (capacity method) and trace water measurement (electric quantity method). Meet the moisture determination requirements for both constant and trace moisture samples, and can analyze two sets of samples simultaneously.
◇ Liquid discharge and replenishment: Button operation for automatic liquid discharge and replenishment
◇ Communication function: Communicate with computers and can be controlled by microcomputers;
◇ According to different sample measurement requirements, balance, accuracy, drip rate, and stirring can be freely set and controlled;
◇ Titration unit: imported from Wantong, Switzerland
◇ Self inspection: The instrument has the function of self diagnosis and measurement, as well as the function of electrolytic electrode faults
◇ Adopting imported motors, pumps, and valves greatly improves the reliability of the product
◇ Increase the function of deducting blank values from dynamic averages.
◇ Add automatic calibration function: This function solves the errors caused by differences in different reagents and decreased reagent sensitivity.
Technical parameters for trace moisture:
Electrolytic control: Automatic electrolytic current control (larger than 400MA); Measurement range: 3UGH 2O~99MGH 2O;
Electrolysis speed: 2.0 milligrams of water per minute; Sensitivity threshold: 0.1 micrograms of water;
Accuracy: 3UG-100UGH 2 O error ± 1UG 100UGH 2 O or above ± 0.5%.
Printing: Wide line micro printer; Resolution: 1 Μ A
Constant moisture technical parameters:
Measurement range: 10PPM-100% Reproducibility: ± 0.01
Result display unit:%, PPM, MG titration * * * Small feed rate: 0.001ML
Titration rate: 0.5MI/s Burette volume: 20ML
Burette resolution: 1/10000, sensitivity threshold: 0.5UGH 2 O;
Drift: Fully automatic real-time measurement instrument Operating environment conditions: ambient temperature 15-30 ℃, humidity ≤ 85%
Power supply voltage: AC220V, 50HZ
External dimensions: 335 x 500 x 550mm (length x width x height)
Product
- Fully automatic distillation range (boiling range) tester
- Harbin New Area Joins Hands with Harbin Engineering to Build Bihai Industrial Park
- The instrument and meter industry is showing a mainstream trend of high-tech development
- What opportunities does China's entry into the WTO bring to the instrument industry? Tianlong Instrument is here to analyze!
- How to bridge the development gap in the instrumentation industry?