很遗憾,因您的浏览器版本过低导致无法获得最佳浏览体验,推荐下载安装谷歌浏览器!

TLYA-20 fully automatic gasoline oxidation stability tester

Manager Liu: 13351885528
Manager Liu: 13945136889
Online More Information
Share:
Keywords: Harbin Tianlong Instrument Manuf           

Product Introduction

Product purpose: To determine the oxidation stability of gasoline (induction period method).


Applicable standards: GB/T 8018-2015, GB/T 8018-2015


Functional characteristics


The instrument is a desktop structure that utilizes the RS232 serial port connection between the PC computer and the instrument host, resulting in a high degree of automation.


The instrument comes with an oxygen bomb holder, which facilitates the operator to disassemble the oxygen bomb cover above it, and also facilitates the placement of the oxygen bomb before and after the test.


Adopting a new metal bath constant temperature technology to replace traditional water bath constant temperature bath, the experiment is vibration free, pollution-free, and does not require liquid replenishment.


A well-designed insulation system not only saves energy but also avoids the risk of burns to operators.


>The integrated design of the oxygen bomb assembly has shortened the oil and gas pressure testing pipeline, making pressure detection more accurate.


During the testing process, the pressure curve is displayed in real-time, and the test results are clear at a glance. Real time collection of pressure data from two test shells and sending it to the main control board for calculation.


Using precision needle valves to control pressure and ensure good sealing.


Non secondary pressure relief valve, automatically relieves pressure when the pressure inside the projectile exceeds 1500kPa, ensuring the safety of the experimenter and instrument. The pressure relief valve will automatically return to its initial state after pressure relief.


After the instrument stops testing, it will automatically cut off the heating power to ensure safety. In addition, a 120C temperature switch is installed in the metal bath. When the bath temperature exceeds 120'C, the instrument will also automatically cut off the heating power. Dual protection, higher security.


Technical indicators:

1. Power supply: AC220V ± 10% 50Hz

2. Heating power: ≤ 1 8KW

3. Temperature control accuracy: 100 0 ± 0.1C

4. Digital pressure range: 0-1600KPa

5. Precision of digital pressure sensor: ± 2%

6. Number of oxygen bombs tested: 2

7. External dimensions: 330X460X500 (mm)


Product

Product

Harbin Tianlong Instrument Manufacturing Co., Ltd,Main Product Product Center And other business,Interested customers please contact us,Phone:13351885528

CopyRight © All Rights Reserved: Harbin Tianlong Instrument Manufacturing Co., Ltd Site Map XML

Site Keywords: Harbin Tianlong Instrument Manufacturing Co. Ltd


Follow us