Electric quantity method, capacity method, moisture meter integrated machine

Manager Liu: 13351885528
Manager Liu: 13945136889
Online More Information
Share:
Keywords: Harbin Tianlong Instrument Manuf           

Product Introduction

Product Usage: Widely used in petrochemical products, food, daily necessities, pharmaceuticals, pesticides, cosmetics, solvents, and other gases and liquids


Body and solid products.


Applicable standards: GB/T623, SH1144, SH/T0086, SH/T1612, GB/T606, SH/T 0246, GB/T3727, GB/T7600.


Performance characteristics:



A full range Karl Fischer apparatus for measuring water content is formed by integrating various methods. Satisfy the requirements for constant and trace moisture samples


Moisture determination requires simultaneous analysis of two sets of samples.




According to different sample measurement requirements, balance, accuracy, drip rate, and stirring can be freely set and controlled;


Titration unit: imported from Wantong, Switzerland


◆ Self check: The instrument has the function of self diagnosis and measurement, as well as electrolytic electrode faults


The use of imported motors, pumps, and valves greatly improves the reliability of the product


Add dynamic average deduction blank function.


Add automatic calibration function: This function solves the errors caused by differences in different reagents and decreased reagent sensitivity Poor.


Technical parameters for trace moisture:


Electrolytic control: Automatic electrolytic current control (less than 400mA)


Measurement range: 3+H20-~99mgH20


Electrolysis speed: 2 0 milligrams of water per minute


Sensitivity threshold: 0 1 microgram of water;


Accuracy: 3ug, 100ug, H20, with an error of 0.5% for soil above 1ug, 100ug, and H20.


Printing: Wide line micro printer


Resolution: 1 μ A


Constant moisture technical parameters:


Measurement range: 10ppm-100%


Reproducibility: Soil 0.01


Result display units:%, ppm, mg


Titration feed rate: 0 001ml


Titration rate: 0 5ml/second


Burette customer volume: 20ml


Burette resolution: 10000


Sensitivity threshold: 0 5ugH20


Drift: Fully automatic real-time measurement


Environmental conditions for instrument use: ambient temperature 15~30 "C, humidity ≤ 85%


Power supply voltage: AC220V, 50Hz


External dimensions: 335 X500X550mm (length x width x height)


Product

Product

Harbin Tianlong Instrument Manufacturing Co., Ltd,Main Product Product Center And other business,Interested customers please contact us,Phone:13351885528

CopyRight © All Rights Reserved: Harbin Tianlong Instrument Manufacturing Co., Ltd Site Map XML

Site Keywords: Harbin Tianlong Instrument Manufacturing Co. Ltd


Follow us